SchO-70 switchboards

SchO-70 LV switchboards are designed to bundle the 0.4 kV 3-phase 50 Hz switchgear with a dead-grounded neutral. The panels serve to receive and distribute the electrical energy, protect from overloads and short circuit currents.

Scope of use:

- urban electric networks

- Power supply for housing and utility service

- Power supply to industrial facilities.

 

Features

- Low price

- Simple and convenient service

- Serviceability

- Switchboards can be manufactured for custom layouts and of any dimensions

 

Design

Standard SchO-70 switchboard is a steel welded structure made of bent sheet profiles with mounting points for electrical equipment.

According to their purpose, there are the following types of SchO-70 switchboards:

- entry;

- sectional;

-linear;

-entry-linear (entry-sectional);

- street lighting dispatcher control;

- with devices for automatic transfer, etc.

The switchboards are of one-side service type, all control of the disconnectors, circuit breakers, devices, and throw switches is facilitated via the drives on the front side of the cabinet with completely closed doors.

Following switching devices can be installed in the switchboard: stationary and withdrawable circuit breakers; throw switches; disconnectors; fuses.

Switchboards are manufactured with prefabricated busbars with peak withstand current of 30 kA (up to 630 kVA) and 50 kA (above 630 kVA). The busbars are located in the upper part of the switchboard and on the front side they are covered with a protective panel where electrical measuring instruments (ammeters, voltmeter) are mounted.

Mounting profile for fixing wires and cables is welded to the lower belt of the switchboard. Bus or cable entry.

In case of two-row arrangement of the SchO-70 switchboards, the installation of bus bridges is provided.

Bus bridge is mounted on the switchboards that face each other and is a metal structure consisting of two supports and base, with support insulators and buses mounted on it. Bus bridges have fencing at the bottom and on the sides to protect from accidental contact with current-carrying buses. Busbar bridges are installed without disconnectors.

Basic technical parameters

SITE NAVIGATION

VIDEO ABOUT TCN-ELECTRO PLANT

IMPLEMENTED PROJECTS

Rated voltage, kV

380/220

Auxiliary circuits rated voltage, V

220

Rated frequency, Hz

50

Current type

AC

Main circuit rated current, A

630 … 4,000

Control circuits rated current, A

Up to 25

Insulation rated voltage, V

660

Rated impulse-withstand voltage, В

2,500

Insulation as per GOST 516.3-96

Normal, level "b"

Insulation of the main circuit busbars

With uninsulated busbars

Grounding system type

TN-С, TN-S, TN-CS

Enclosure protection class as per GOST 14254-96

front and sides  - IP 20; rest - IP00

Service type

One-side

Control type

Local

Dimensions (H х W х L), mm:

2,200 х 400 (600, 800, 1,000) х 600

Max. weight, kg:

- entry and sectional switchboards

- linear switchboards

- street lighting dispatcher control switchboard;

- automatic transfer switchboards

 

300

170

80

100

Climatic modification as per GOST 15150

UZ

Ambient operating temperature, °С

+40 … -40

Max. altitude above sea level, m

1,000

Service life, years

30

GEOGRAPHY OF DELIVERIES

CATALOGUE PRINTED VERSION

©1999-2018 ООО TCN-electro

 

Sale Department for the Nizhny Novgorod region: +7 (831) 275-888-9

Regional sale department (Russia and CIS countries): +7 (495) 789-49-68

 

7 A, ul. Elektrovoznaya, Nizhny Novgorod, Russia, 603108